Cummins VEPS VCP 7.70 :
CUMMINS VCP 7.7 
 
This version of the VEPS software was created to support 2010 Cummins engines plus new parameters for Euro 5 engines and ISZ CM2150E. 
 
New in Version 7.7 
 
Starting with this release, VEPS will automatically upgrade previous installations to the latest version. It is no longer necessary to unistall an existing installation of VEPS before installing VEPS 7.70 or later versions. 
 
2007 ECMs:  
 
New Engine programs supported:  
CM2250(BBN,BBO,BBP,BBZ) and CM2150E(BAM) 
 
New features: 
                                                      MR-2010(CM2250)  HDD-2010(CM2250)   MR-Euro5(CM2150E)    HDD-ISZ(CM2150E) 
- 50037 - Switched Maximum Vehicle Speed                     Y             Y                               
- 50038 - Switched Maximum Road Speed Setting                Y             Y 
- 50040 - Variable Rate Vehicle Acceleration Management      Y             Y              Y                    Y                     
- 50041 - Variable Acceleration 1                            Y             Y              Y                    Y 
- 50042 - Variable Acceleration 2                            Y             Y              Y                    Y 
- 50043 - Variable Acceleration Speed 1                      Y             Y              Y                    Y 
- 50044 - Variable Acceleration Speed 2                      Y             Y              Y                    Y 
- 50045 - Urea Tank Heater 1 Relay                           Y                            Y                    Y                      
- 50046 - Linear Urea Tank Volume                            Y                            Y                    Y                            
- 50047 - Urea Tank Type                                     Y                            Y                    Y 
- 500481 - Non Linear Urea Tank Level X 1                    Y                            Y                    Y 
- 500482 - Non Linear Urea Tank Level X 2                    Y                            Y                    Y 
- 500483 - Non Linear Urea Tank Level X 3                    Y                            Y                    Y 
- 500484 - Non Linear Urea Tank Level X 4                    Y                            Y                    Y 
- 500485 - Non Linear Urea Tank Level X 5                    Y                            Y                    Y 
- 500486 - Non Linear Urea Tank Level X 6                    Y                            Y                    Y 
- 500487 - Non Linear Urea Tank Level X 7                    Y                            Y                    Y 
- 500488 - Non Linear Urea Tank Level X 8                    Y                            Y                    Y 
- 500489 - Non Linear Urea Tank Level X 9                    Y                            Y                    Y 
- 5004810 - Non Linear Urea Tank Level X 10                  Y                            Y                    Y 
- 5004811 - Non Linear Urea Tank Level X 11                  Y                            Y                    Y 
- 500491 - Non Linear Urea Tank Volume Y 1                   Y                            Y                    Y                                      Y                   Y 
- 500492 - Non Linear Urea Tank Volume Y 2                   Y                            Y                    Y 
- 500493 - Non Linear Urea Tank Volume Y 3                   Y                            Y                    Y 
- 500494 - Non Linear Urea Tank Volume Y 4                   Y                            Y                    Y 
- 500495 - Non Linear Urea Tank Volume Y 5                   Y                            Y                    Y 
- 500496 - Non Linear Urea Tank Volume Y 6                   Y                            Y                    Y 
- 500497 - Non Linear Urea Tank Volume Y 7                   Y                            Y                    Y 
- 500498 - Non Linear Urea Tank Volume Y 8                   Y                            Y                    Y 
- 500499 - Non Linear Urea Tank Volume Y 9                   Y                            Y                    Y 
- 5004910 - Non Linear Urea Tank Volume Y 10                 Y                            Y                    Y 
- 5004911 - Non Linear Urea Tank Volume Y 11                 Y                            Y                    Y 
- 50050 - Urea Tank Heater 2 Relay                           Y                            Y                    Y 
- 50051 - Urea Line Heater 1 Relay                           Y                            Y                    Y 
- 50052 - Urea Line Heater 2 Relay                           Y                            Y                    Y 
- 50053 - Enhanced Auxiliary Shutdown Switch                 Y             Y              Y 
- 50054 - Enhanced Auxiliary Shutdown Switch Logic           Y             Y              Y         
- 50055 - Enhanced Multiplexed Auxiliary Shutdown Switch     Y             Y              Y   
- 50056 - Enhanced Auxiliary Shutdown Switch Multiplexed     Y             Y              Y  
                                                 Address 
- 50057 - Idle Shutdown Service Brake Switch                 Y                            Y  
- 50061 - Regeneration with Parking Brake                                  Y 
- 24011 - Immobilizer                                                    
- 50029 - Kickdown Pedal Smart Road Speed Governor 
- 50030 - Smart Road Speed Governor 2                        Y             Y              Y                    Y 
- 50016 - Load Based Speed Control - Enhanced                              Y              Y                    Y 
- 50027 - Low Engine Speed Breakpoint - Enhanced                           Y              Y                    Y 
- 50028 - High Engine Speed Breakpoint - Enhanced                          Y              Y                    Y 
 
Bug fixes: 
- 25771 - Dual Accelerator Pedal Enable, didn't work correctly with its related user selectable. fixed. 
 
_________________________________________________________________________________________________________ 
CUMMINS VCP 7.6   
 
This revision of the VEPS software was created to support European Level5 emissions applications. It also added three new parameters described below. 
 
New in version 7.6 
 
2007 ECMs: 
 
New Engine programs supported: 
ISBe Euro 4.5/5, ISLe Euro 4.5/5 
  
New feattures: 
  - 50005 - Parking Brake Switch 
  - 50018 - Oil Level Electronic Dipstick Engine Power Angle 
  - 50019 - Oil level Electronic Dipstick Horizontal Engine Tilt Angle 
  - 50017 - Oil Level Electronic Dipstick Oil Pan Type 
  - 50021 - Oil Level Electronic Dipstick Oil Pan Port Location 
  - 50022 - Oil Level Sensor Enhanced 
  - 50029 - Smart RSG Extension Kickdown Pedal                                                                    
  - 50030 - Smart Road Speed Governor 2    
  - 50023 - Cruise Control without Parking Brake Set 
  - 50025 - PTO with Parking Brake Set 
  - 24011 - Immobilizer 
  
  For both Euro4.5/5 and 07 engines 
  - 50026 - Fan on With Remote Throttle 
  - 15181 - Switched Maximum Engine Operating Speed Enable 
  - 15182 - Maximum Switched Engine Speed 
 
Bug fixes: 
  - Common Components have been updated to version 1.12.3 to fix communication error when using NEXIQ and DearBorn data link adapters to communication with Cummins ECM  
  - updated DE0201.dll for 04 Engines (ISC 03, ISL03, ISM 02, ISX 02 and ISM 04) to fix communication failure error when using 7.53 
  - 23002 - Isochronous Breakpoint Speed. The parameter used to be named as "Maximum Switched Engine Speed", which refers to a different parameter in InSite 
 
Pre 2007 ECMs: 
   not changed 
______________________________________________________________________________________________________ 
New in Version 7.53 
 
2007 ECMs: 
 
New features: 
- Passwords:  Adjustment and Reset can be '000000' (default disabled password value) if Master is also '000000' 
- Passwords:  All passwords can be 1-6 in length.  It will be padded to with 0x00s to the right.  Example - ['M']['M'] --> ['M']['M'][0x00][0x00][0x00][0x00] 
- 12300 has been added to the documentation file.  This was not included in previous documents, but was supported in the software. 
- Grid Heater Enable (30500) is now supported in VEPS for 2007 engines, where the calibrations also support it. 
- All the Min/Max ranges and default values have been removed from 2007 engine documentation released with VEPS.  This is to avoid confusion when a new calibration is released and VEPS documentation is out of date.  Please consult the GCE website which has updated calibration documentation for the latest values. 
 
Bug fixes: 
- 15460 has been removed from VEPS support.  Parking Brake PTO Enable is not a valid parameter. 
 
 
Pre 2007 ECMs: 
 
- CM800 Euro3 and CM850 Euro4 - Added support for Load Based Speed Control (10040) 
- CM850 Euro4.5 - Added support for the following parameters 
	12000 - Oil Level Electronic Dipstick 
	12001 - Oil Level Electronic Dipstick Engine Power Angle 
	12002 - Oil Level Electronic Dipstick Engine Min Power Angle 
	12003 - Oil Level Electronic Dipstick Engine Max Power Angle 
	12011 - Oil Level Electronic Dipstick Oil Pan Type 
	12012 - Oil Level Electronic Dipstick Oil Pan Location 
	12031 - Oil Level Electronic Dipstick Horizontal Engine Tilt Angle 
	12032 - Oil Level Electronic Dipstick Min Tilt Angle 
	12033 - Oil Level Electronic Dipstick Max Tilt Angle 
	12100 - Intake Air Heater 
 
 
_____________________________________________________________________________________________________ 
 
New in Version 7.52 
 
2007 ECMs: 
 
New features: 
- Added new parameters 30090 Coolant Level Configuration and 30190 Coolant Level Mux Address. 
- Added support for unlocking and changing 2007 OEM Password. 
- Allow for same Par file to be used again even when setting core2 Master Password or OEM Password. 
 
Bug fixes: 
- (11440) bug:  If (10000) = (11440) = (11430), when 10000 is lowered and 11440 is in the par file and not set below 10000 along with 11430, then VEPS errors out.  This is fixed so that 11440 and 11430 are moved to 10000's value if they are in the par file and a warning is given for each. 
- When the latest version of the Cummins engineering tool was installed on the same PC as the VCP software, Multiplexing values were not written to the ECM by the VCP software due to a newer version of a shared library installed on the PC.  This issue has been resolved so that regardless of the version of the shared library, the Multiplexing values will be registered in the ECM. 
- Display name for Battery Voltage Monitor changed to Alternator Failure Warning to match INSITE naming convention. 
 
Range fixes: 
- The Max value for (30311) is the difference of (13590) and (10090). 
- Corrected max value for TI_MPH_Overspeed_1 (12940) and TI_MPH_Overspeed_2 (12950) from 16383.8 to 10180.4 m/h. 
 
 
 
Pre 2007 ECMs: 
 
- CM800 Echo modules would at times not send all the bytes in the feature table (AENBLFLG) to the VCP software.  Checks have been added to make sure this does get read.  If it doesn't after 6 tries then it will error out.  If all goes well, this adds less than 4 seconds to the full programming of a pre-2007 ECM. 
 
 
_____________________________________________________________________________________________________ 
 
New in Version 7.51 
 
This revision of the VEPS software was created to support: 
 
The 2007 Automotive products:  ISB, ISC, ISL, ISM, ISX 07. 
 
The main focus of this release is to add support for the new Aftertreatment features and parameters.  Also, there have been parameters that have been added that were missed in previous releases. 
 
The following parameters were added to the VEPS software: 
 
11090	PTO Device 1 
11091	PTO Device 2 
11092	PTO Device 3 
11093	PTO Device 4 
11094	PTO Device 5 
11095	PTO Device 6 
11096	PTO Device 7 
11097	PTO Device 8 
12940	Vehicle Overspeed 1 
12950	Vehicle Overspeed 2 
14560	Fast Idle Warmup PTO Load Threshold 
14570	Fast Idle Warmup Idle Speed 
15180	Maximum Operating Speed Switch Setup 
15432	Idle Shutdown with Parking Brake ON 
15434	Engine Brake Lamp 
15460	PTO with Parking Brake ON 
22571	Battery Voltage Monitor 
22581	Battery Voltage Monitor Idle Speedup 
23002	Maximum Switched Engine Speed 
23121	Switched Droop Enable 
24051	Vehicle Acceleration Management 
25281	Fast Idle Warmup 
25571	OEM Temperature Input Enable 
25581	OEM Pressure Input Enable 
25771	Dual Accelerator Pedal Enable 
27021	J1939 Trip Reset 
27031	J1939 Service Reset 
27041	J1939 Stop Broadcast Allowed 
30077	Diesel Particulate Filter Regeneration Start Switch 
30078	Multiplexed Aftertreatment Regeneration Start Switch 
30087	Diesel Particulate Filter Regeneration Permit Switch 
30088	Multiplexed Aftertreatment Regeneration Permit Switch 
30097	Automatic Stationary DPF Regeneration 
30107	DPF Regeneration in PTO 
30117	DPF Regeneration Lamp 
30178	Aftertreatment SRegen Switch Multiplexed Address 
30188	Aftertreatment Permit Regen Switch Multiplexed Address 
30207	Aftertreatment HEST Lamp Setup 
30208	HEST Lamp Setup When Regen In Progress 
30211	HEST Lamp Setup Vehicle Speed 
30212	HEST Lamp Setup Low Threshold 
30213	HEST Lamp Setup High Threshold 
30307	Driver Initiated Override 
30311	Driver Initiated Override Max Road Speed Delta 
30312	Driver Initiated Override Max Distance 
99000	Fuel Log Enable 
99002	Trip Information Vehicle Enable 
199251	Acceleration Rate 
 
 
_____________________________________________________________________________________________________ 
 
New in Version 7.5 
 
This revision of the VEPS software was created to support: 
the 2007 ISB & ISC/ISL programs; 
additional parameters in the Tier3 Core 2 programs and the Echo program; 
Adjustment and Reset passwords and Engine Serial Number for Core 2 Automotive programs; 
and some performance and error handling issues in past releases. 
 
New Engine programs supported: 
-	2007 ISB & ISC/ISL programs. 
	 
Changes For all Engine Programs 
-	None 
 
Verification File Change  
-	None 
 
ISM 07 ISX 07 
-	Added support for setting Adjustment (00024) and Reset (00021) Passwords 
-	Added support for Setting Engine Serial Number (3003) 
-	Added additional Fan Clutch Type Options (12490) 
 
ISB 07 
-	All parameters supported in ISM/ISX 07 are supported in ISB 07 (unless the specific calibration does not) 
-	Added support for setting Adjustment (00024) and Reset (00021) Passwords 
-	Added support for Setting Engine Serial Number (3003) 
-	Added additional Fan Clutch Type Options (12490) 
 
ISC 07 ISL 07 
-	All parameters supported in ISM/ISX 07 are supported in ISC/ISL 07 (unless the specific calibration does not) 
-	Added support for setting Adjustment (00024) and Reset (00021) Passwords 
-	Added support for Setting Engine Serial Number (3003) 
-	Added additional Fan Clutch Type Options (12490) 
 
ISBe4 ISLe4 ISMe4 
-	None 
 
QSB QSC QSL (Tier III) 
-	Added support for 10050, 10060, 10070 
 
All EGR Engine Programs 
-	None 
 
ISM 02 ISX 02 
-	None 
 
ISB 02 ISC 03 ISL 03 
-	None 
 
ISBe 
-	Added support for 15460 and 21251. 
 
 
ISC / ISL 
-	None 
 
Natural Gas Engines 
-	None 
 
QSB / QSC 
-	None 
 
Heavy Duty 
-	None 
 
Known Issues 
-	None 
 
This setup utility will install all components needed to program ISB, ISC, ISBe, ISL, M11, N14, ISM, ISX, QSB, QSC, QSC 04, QSL 04, QSM, QSX, C8.3G+, B5.9G+, L10G+, Signature 600, ISB 02, ISC 03, ISL 03, ISX 02, ISM 02, ISM 04, ISB 07, ISC 07, ISL 07, ISM 07 and ISX 07 engines. 
 
_____________________________________________________________________________________________________ 
 
New in Version 7.4 
 
This revision of the VEPS software was created to support the remaining parameters of the 2007 ISM/ISX program. 
 
New Engine programs supported: 
-	None 
	 
Changes For all Engine Programs 
-	Each execution of VEPS will now create a comma separated value text file of the VEPS report. By default the file will be named ceco600.vrp. Use the -r to specify the report file name. 
 
Verification File Change  
-	None 
 
ISM 07 ISX 07 
-	Added support for the complete set of adjustable parameters. See the document "ISM ISX 07 Programmers Reference manual" for a complete list of parameters. 
 
ISBe4 ISLe4 ISMe4 
-	Corrected the software version check that was preventing the support of some Euro 4 parameters. 
 
QSB QSC QSL (Tier III) 
-	Added support for 10000, Maximum Accelerator Vehicle Speed. 
-	Corrected a bug that prevented the user from changing 40200, 40210 and 40220. 
 
All EGR Engine Programs 
-	Added support for 15432, Idle Shutdown with Parking Brake ON. 
-	Removed the requirement that 15460, PTO with Parking Brake ON be multiplexed. 
-	Removed the requirement that 20011 (PTO) be enabled before programming PTO parameters. This allows customers to setup PTO without turning it on. 
-	Added support for 27021, J1939 Trip Reset. 
-	Added support for 27031, J1939 Service Reset. 
-	Added support for 27041, J1939 Stop Broadcast Allowed. 
 
ISM 02 ISX 02 
ISB 02 ISC 03 ISL 03 
ISBe 
ISC / ISL 
Natural Gas Engines 
QSB / QSC 
Heavy Duty 
-	None 
 
Known Issues 
-	None 
 
This setup utility will install all components needed to program ISB, ISC, ISBe, ISL, M11, N14, ISM, ISX, QSB, QSC, QSC 04, QSL 04, QSM, QSX, C8.3G+, B5.9G+, L10G+, Signature 600, ISB 02, ISC 03, ISL 03, ISX 02, ISM 02, ISM 04, ISM 07 and ISX 07 engines. 
 
_____________________________________________________________________________________________________ 
 
New in Version 7.33  
 
This revision of the VEPS software was created to fix Write Verification Errors reported by the field. 
 
Changes For all Engine Programs 
- If any Write Error occurs, attempt to write the value one more time before reporting an error. 
 
This setup utility will install all components needed to program ISB, ISC, ISBe, ISL, M11, N14, ISM, ISX, QSB, QSC, QSC 04, QSL 04, QSM, QSX, C8.3G+, B5.9G+, L10G+, Signature 600, ISB 02, ISC 03, ISL 03,ISX 02, ISM 02, ISM 04, ISM 07 and ISX 07 engines. 
 
_____________________________________________________________________________________________________ 
 
New in Version 7.32  
 
This revision of the VEPS software was created to fix Write Verification Errors reported by the field. 
 
Changes For all Engine Programs 
- If a Write Verification Error occurs, attempt to write the value one more time before reporting the error. 
 
This setup utility will install all components needed to program ISB, ISC, ISBe, ISL, M11, N14, ISM, ISX, QSB, QSC, QSC 04, QSL 04, QSM, QSX, C8.3G+, B5.9G+, L10G+, Signature 600, ISB 02, ISC 03, ISL 03,ISX 02, ISM 02, ISM 04, ISM 07 and ISX 07 engines. 
 
_____________________________________________________________________________________________________ 
 
New in Version 7.3  
 
This revision of the VEPS software was created to support Heavy Duty (ISM/ISM) 2007 applications. This release supports a subset of the complete list of 2007 parameters. The rest will be supported in the next release. 
 
New Engine programs supported: 
- ISM / ISX 07 (No J1708/J1587 support, MUST be programmed via J1939) 
 
Verification File Change  
- Error 0955 - The value being assigned this parameter is not defined as a valid setting in this calibration. 
 
ISM07 ISX 07 (Only programmable via J1939) 
- 30000 is no longer required or supported 
- 30008-30034 Have changed from Y/N enables to accepting values 0, 128-133. Use 128 for standard J1939 Multiplexing. 
Added support for the following parameters: 
1001 - OEM Name 
1003 - OEM Vehicle or Equipment Model 
1005 - VIN or equipment serial number 
1006 - Vehicle or equipment year  
1009 - Customer name 
1010 - Customer location 
1011 - Customer unit number 
10000 - Maximum Accelerator Vehicle Speed 
10020 - Maximum Engine Speed Without VSS 
10030 - Low Idle Speed 
10050 - Rear Axle Ratio 
10060 - Tire size 
10070 - Tailshaft Teeth 
10080 - VSS Type 
10090 - Maximum Cruise Control Speed 
10100 - Set/Resume Switch Usage 
10130 - PTO Maximum Speed 
10170 - Idle Shutdown Timer 
10300 - Top Gear Ratio 
10790 - Clutch Switch 
11340 - Gear Down Gear Ratio 
11390 - PTO Minimum Speed 
11410 - Transmission Type 
11540 - Engine Brake Minimum Vehicle Speed 
12490 - Fan Type 
12780 - Fan Clutch Logic 
12790 - Driveline Brake Type 
13590 - Maximum Vehicle Speed 
20001 - Low Idle Speed Switch 
 
20011 - PTO 
20021 - Cruise Control 
20051 - Idle Shutdown 
20071 - Idle Shutdown in PTO 
20081 - Idle Shutdown Manual Override 
20571 - Coolant Level Sensor 
21461 - Fan Control Switch 
21712 - Air Conditioning Pressure Switch Input 
22221 - Fan Control 
23021 - Engine Brakes 
30008 - Multiplexed Service Brake Switch 
30010 - Multiplexed Clutch Pedal Position Switch 
30012 - Multiplexed Cruise Control On/Off Switch 
30014 - Multiplexed Cruise Control Set Switch 
30016 - Multiplexed Cruise Control Resume Switch 
30018 - Multiplexed PTO On/Off Switch 
30020 - Multiplexed PTO Set Switch 
30022 - Multiplexed PTO Resume Switch 
30034 - Multiplexed Fan Control Switch 
30106 - Service Brake Switch Multiplexed Address 
30108 - Clutch Pedal Position Switch Multiplexed Address 
30110 - Cruise Control On/Off Switch Multiplexed Address 
30112 - Cruise Control Set Switch Multiplexed Address 
30114 - Cruise Control Resume Switch Multiplexed Address 
30116 - PTO On/Off Switch Multiplexed Address 
30118 - PTO Set Switch Multiplexed Address 
30120 - PTO Resume Switch Multiplexed Address 
30132 - Fan Control Switch Multiplexed Address 
40220 - Remote Accelerator Mode 
 
ISBe4 / ISLe4 / ISMe4 
21701  Adaptive Cruise Control Enable 
11712  Adaptive Cruise Control Recovery 
 
Known Issues 
11540 - Engine Brake Minimum Vehicle Speed reports that is successfully programmed, but when checked, it hasnt changed. 
 
10090 - Maximum Cruise Control Speed, the tool upper limit defined in the latest released calibration is 0, so VEPS will automatically set 10090 to 0. 
 
This setup utility will install all components needed to program ISB, ISC, ISBe, ISL, M11, N14, ISM, ISX, QSB, QSC, QSC 04, QSL 04, QSM, QSX, C8.3G+, B5.9G+, L10G+, Signature 600, ISB 02, ISC 03, ISL 03,ISX 02, ISM 02, ISM 04, ISM 07 and ISX 07 engines. 
 
_____________________________________________________________________________________________________ 
 
New in Version 7.2  
 
This revision of the VEPS software was created to support European Level 4 emissions applications. It also contains minor revisions to three parameters described below. 
 
All EGR Engine Programs 
- Added support for 15320  Vehicle Speed Signal Tampering Sensitivity Level. 
  
ISC / ISL 
- Added support for 21221 - Accelerator Interlock. 
 
Heavy Duty 
- Removed the requirement that said 12479  Top 2 Enable must be ENABLED for 11410  Transmission Type to be set to option 3  Partially Automated. 
  
ISBe4 / ISLe4 / ISMe4 
- Added support for European Level 4 emissions applications: 
15500  Euro Smart Road Speed Governor 
23241  Switched Speed Road Speed Governor 
14240  Maximum Secondary Vehicle Speed without Cruise Control Active 
25791  Acceleration Rate Variable Limit 
15421  Acceleration Rate Speed 1 
15422  Acceleration Rate Speed 1 Rate Limit 
15423  Acceleration Rate Speed 2 
15424  Acceleration Rate Speed 2 Rate Limit 
15430  Idle Shutdown Coolant Temperature 
15431  Idle Shutdown Coolant Temperature Value 
25201  Cruise Control with Parking Brake OFF 
15460  PTO with Parking Brake ON 
25771  Dual Accelerator Pedal 
20591  Vehicle Electrical System Voltage 
24011  Immobilizer 
15480  Maximum Engine Speed Droop Option 
15212  Real Time Clock 
15470  Real Time Clock From Datalink 
15471  Real Time Clock From Datalink Source Address 
25781  Urea Heater 
25801  Non-Linear Urea Tank Type 
15510  Linear Urea Tank Volume 
15520  OEM Volume Input 1 
15521  OEM Volume Input 2 
15522  OEM Volume Input 3 
15523  OEM Volume Input 4 
15524  OEM Volume Input 5 
15525  OEM Volume Input 6 
15530  Percent Calibrated Volume Input 1 
15531  Percent Calibrated Volume Input 2 
15532  Percent Calibrated Volume Input 3 
15533  Percent Calibrated Volume Input 4 
15534  Percent Calibrated Volume Input 5 
15535  Percent Calibrated Volume Input 6 
 
This setup utility will install all components needed to program ISB, ISC, ISBe, ISL, M11, N14, ISM, ISX, QSB, QSC, QSC 04, QSL 04, QSM, QSX, C8.3G+, B5.9G+, L10G+, Signature 600, ISB 02, ISC 03, ISL 03, ISM 02, ISM 04 and ISX 02 engines. 
 
_____________________________________________________________________________________________________ 
 
New in Version 7.1  
 
Added support for the Remote Accelerator Mode parameter to the QSC/QSL 04 DLL. Added support for the J1939 Multiplexing Auxiliary Shutdown Switch to Natural Gas Engines. A problem with the Cummins VCP control panel applet has been fixed. 
 
Natural Gas Engines 
- Added support for J1939 Multiplexing Auxiliary Shutdown Switch 
 
QSB / QSC 04 
- Added support for Remote Accelerator Mode 
 
This setup utility will install all components needed to program ISB, ISC, ISBe, ISL, M11, N14, ISM, ISX, QSB, QSC, QSC 04, QSL 04, QSM, QSX, C8.3G+, B5.9G+, L10G+, Signature 600, ISB 02, ISC 03, ISL 03, ISM 02, ISM 04 and ISX 02 engines. 
 
_____________________________________________________________________________________________________ 
 
New in Version 7.0  
 
The biggest change in this version is the new support for QSC/QSL 04 Multi-Accelerator feature. There were also several enhancements ISBe program. Some VEPS base code bug fixes and enhancement were also completed. 
 
New Engine programs supported: 
- QSC/QSL 04 
	 
Changes For all Engine Programs 
- VEPS will not create a read-only error if the value in the par file matches the value in the ECM. 
 
- When VEPS is run by a user without administration rights, VEPS will still use the VCP settings set by a user with administration rights. 
 
- Allow programming "Minimum AC Fan On Time" even if it is not enabled. 
 
- Wrap dataplate values that don't fit in the defined column width. 
 
- No longer require that gear ratio low is lower than gear ratio high. 
 
All EGR Engine Programs 
  
ISX 02 
- Added support for the new Variable Speed Fan Types. 
 
ISB 02 
 
ISC 03 - ISL 03 
 
- Added support for Adaptive Cruise 
 
ISBe 
- Use the calibration tool limits on PTP axle torque limit. 
 
- Allow programming PTO and PTP trims even if the feature is disabled. 
 
- Added ECM Part Number, ECM Serial Number, SC option and DO option as read only parameters. 
 
Natural Gas Engines 
 
QSB / QSC 
 
Heavy Duty 
  
Known Issues 
 
- On WIN 98 and WIN ME operating systems, if the VCP configuration option "Write Trace / Debug Information" is selected, it will cause a page fault when VEPS exits. 
 
This setup utility will install all components needed to program ISB, ISC, ISBe, ISL, M11, N14, ISM, ISX, QSB, QSC, QSC 04, QSL 04, QSM, QSX, C8.3G+, B5.9G+, Signature 600, ISB 02, ISC 03, ISL 03, ISM 02, ISM 04 and ISX 02 engines. 
 
VCP User Guide PDF 
 
 | 
	
 |